Installation in the Insulation Layer

Warm mounting beam

The Marbet Warm Mounting Beam is the ideal solution for airtight window installation, meeting the highest standards of investors. High-quality warm installation simplifies reducing heat loss and achieving significant savings in building maintenance costs.

Comprehensive Solution
CBM system is a thermal insulation load-bearing frame – a new extended window reveal that permanently connects window frames with the existing wall. Additionally, for double-layer walls, it meets the requirements for NRO (Non-Spreading of Fire from the Outside).
Safe System
CBM is a system of steel load-bearing brackets and complementary materials that work elastically, ensuring the highest standards in strength, tightness, and thermal performance of connections.
Easy to Install
CBM is an installer-friendly system that compensates for wall unevenness or curvature, featuring various improvements that make installation easier – based on the principle of “building with blocks.”
Economical and Durable
CBM is a warm and airtight mounting solution that reduces heat loss and allows significant savings in building maintenance costs – a solution confirmed by aging tests.

Minimizing Heat Loss and Ensuring Airtight Connections in Energy-Efficient Construction

Energy-efficient construction focuses on minimizing heat loss caused by thermal bridges and ensuring airtight connections. Installing windows and doors with excellent insulating properties alone is not enough. For proper installation, it is recommended to position windows and balcony doors beyond the wall face (into the building’s external insulation zone) and to ensure airtight connections between window or door frames and the wall.

marbet bausystem produkty

Innovative Window and Door Installation System

The innovation of Marbet’s window and door installation system lies in its modular design, based on rigid EPS polystyrene Warm Mounting Beams (CBM). This system expands the reveal by creating an airtight support frame constructed from these modular elements, akin to building blocks. Together with complementary components like the threshold beam (BP), internal (PPW) and external (PPZ) windowsill bases, and widely available construction materials such as adhesives, PU foams, mounting connectors, and sealing tapes, the CBM system enables airtight and straightforward installation of modern windows and doors.

Certificates and Standards

The Warm Installation Beam system was developed in collaboration with experienced professionals, including installers and window manufacturers, to meet the highest market requirements. Installing windows and doors using CBM complies with ITB guidelines and has received the National Technical Assessment, ensuring the durability and safety of the structure.

Additionally, the Warm Installation Beam has been certified by the Passive House Institute in Darmstadt as a certified component for passive house construction. This certification guarantees top-quality and energy efficiency, meeting the demands of modern construction.

CBM Assortment

Material: EPS
Density: ≥ 40 kg/m3;
CS(10)300: ≥ 300 kPa
λD ≤ 0,032W/mK;

*) – for BP HARD
Density: ≥ 60 kg/m3
CS(10)600: ≥ 600 kPa
λD ≤ 0,034 W/mK

CBM MARBET Product Range
type of element (width of the jamb)
10 cm 20 cm
Length of the CBM beam 25 cm 70 cm 25 cm 70 cm
Bam with an internal bracket CBM.10.25.W CBM.10.70.W CBM.20.25.W CBM.20.70.W
Beam with an external bracket CBM.10.25.Z CBM.10.70.Z CBM.20.25.Z CBM.20.70.Z
Elements that complement the CBM system
Beam without a bracket CBM.10.25 CBM.10.70 CBM.20.25 CBM.20.70
Under-sill beam:
– BP
– BP.HARD *)
The base of the inner window sill (PPW)
PPW
The base of the outer window sill (PPZ)
PPZ
Nib (W)
W

Complementary products

When ordering the Warm Installation Beam, you can also choose complementary installation products that ensure the desired airtightness and load-bearing parameters. This guarantees a durable, safe, and efficient installation. Click below to view the full range!

Downloads

Complete technical materials and documentation for the Warm Installation Beam system. Here, you’ll find detailed instructions, CAD/BIM models, test results, specifications, and certifications to aid in the design and implementation of your project. Click below to download the necessary documents.

CBM Installation

Option 1 - two-tier wall

The type of CBM beams is selected depending on the type of material from which the exterior wall is made, the assumed depth of injecting the joinery and anticipated loads i.e. with external bracket – symbol CBM…Z or with internal bracket – symbol CBM…W. Below is an example of selection of a CBM beam:

CBM.10.Z Beam – CBM beam with anchor attached to the face of the wall (in the elevation plane) – protrusion of 10 cm

Option 2 - three-tier wall

CBM.20.W Beam – CBM beam with anchor attached in the window opening (in the jamb plane) – protrusion of 20 cm

Assembly sequence for the external jamb according to the CBM system

Outline of mounting the window frame with CBM beams

Mounting to the CBM through a under-sill beam (down) OR mounting directly to the CBM (sides and top)